[1] EPIC, 2012 Insulated panels for external roof and wall cladding, A guide to fire safety and performance in fire, PART 1.
[2] Surrey Fire Services, Construction Fire Safety Plan Bulletin, 2013
[3] Dubai, Department of Planning & Development, Fire Protection, Fire Prevention & Fire/Emergency Control Regulations (2012 Edition), Requirements for Temporary buildings, Facilities or Structures at Construction sites for the use of Offices & Labour Accommodation.
[4] Chow W.K., Fire Hazard assessment on polyurethane sandwich panels for tempory accommodation units, Polymer Testing, 23, 973-977, 2004.
[5] Babrauskas V., Sandwich Panel Performance in Full-scale and Bench-scale Fire Tests, Fire and Materials, Vol.21, 53-65, 1997.
[6] Petrella R.V., The assessment of full-scale fire hazards from cone calorimeter data, Journal of Fire Science, Vol.12, 14-42, 1994.
[7] Checchin M. Cecchini C. Cellarosi B. and Sam F.O., Use of cone calorimeter for evaluating fire performances of polyurethane foams, Polymer Degradation and Stability, 64, 573-576, 1999.
[8] Wittbecker, Daems and Werther. Performance of Polyurethane (PUR) building products in fires. European Isocyanate Producers Association (ISOPA), http:// www.isopa.org.
[9] Bakhtiyati, S., Taghi-Akbari L., Veiseh S., Research Report, BHRC publication No. R-547, 2011 Properties and application of Polyurethane Sandwich Panels and Thermal insulation in buildings and related fire safety recommendation (in Persian).
[10] ISIRI 7271-4, 2005 Reaction to fire for building materials and products- Test methods, part -4: Ignitability of products subjected to direct impingement of flame -: Single-flame source test (in Persian).
[11] ISIRI 11621, 2008 Reaction to fire for building materials and products- Test methods, Building products excluding floorings exposed to the thermal attack by a single burning item (SBI) (in Persian).
[12] INSO 8299-1, 2016 building products and elements- part: 1- Reaction to fire classification (in Persian).
[13] ISIRI 12055-1, 2009 Fire resistance tests-part: 1- General requirements (in Persian).
[14] ISIRI 12245-1, 2009 Fire resistance tests for non-loadbearing elements -part: 1- Walls (in Persian).
[15] Sundström, B., 2007 Doctoral Thesis, The Development of a European Fire Classification System for Building Products – Test Methods and Mathematical Modelling, Department of Fire Safety Engineering, Lund University, Sweden, Lund.
[16] D'Albani, A.W., 2017 Mass Mass loss and flammability of insulation materials used in sandwich panels during the pre-flashover phase of fire, Fire and Materials, 2017.
[17] Bakhtiyati, S., Taghi-Akbari L., Jamali Ashtiani M., 2013 Classification of building materials and products based on reaction to fire performance, Research digests., BHRC publication No:R-724 (in Persian).
[18] ISO 13784-1. 2002 Reaction-to-fire tests for sandwich panel building systems - Part 1: Test method for small rooms.
[19] ISO 13784-2. 2002 Reaction-to-fire tests for sandwich panel building systems - Part 2: Test method for large rooms.