Effect of Freeze–Thaw Cycles on FRP-Concrete Bond Strength in EBR and EBROG Systems

Document Type : Original Research

Authors
1 Municipal employee
2 Professor., Dept. of Civil Engineering, Isfahan Univ. of Technology (IUT)
Abstract
Numerous studies have been devoted to the investigation of the deterioration and behavior of fiber-reinforced polymer (FRP) sheets (made from a variety of materials such as carbon, glass, or aramid) bonded onto the concrete substrate under a variety of adverse environments. Results indicate that environmental conditions might exercise significant and undesirable effects on FRP-concrete bond performance. In many corrosive environments, there are the potential risks of premature debonding and failure of the bonding interface in externally bonded FRP-strengthened concrete structures. The effects of freeze–thaw cycles on the fiber-reinforced polymer (FRP)-to-concrete bond strength were investigated using the particle image velocimetry (PIV) technique. For this purpose, 18 specimens were prepared, including 12 specimens strengthened with carbon FRP (CFRP) strips as well as six control specimens subjected to 200 and 500 freeze–thaw cycles, each consisting of four steps according to ASTM C 666. In the first stage, the temperature was held constant at 5°C for 4.2 h. The next step involved rapid freezing to ‒18°C for 2.4 h. In the third step, the temperature was held constant at ‒18°C for 2.4 h. Finally, the temperature was raised and maintained at 5°C for 3 h in the fourth step. The freeze–thaw under wet conditions was selected in order to create harsher conditions than the dry freeze–thaw conditions would. According to ASTM C 666, the specimens were stored in saturated lime water from the time of their removal from the molds until the time of freezing and thawing tests started. In addition, the nominal freezing and thawing cycle consisted of alternately lowering the temperature of the specimens from +5 to −18°C and raising it from −18 to +5°C in not less than 2 nor more than 5 h. The freezing and thawing chamber was equipped with a user defined program. The temperature range of the chamber was −30°C to +65°C. The temperature was controlled by a sensor, which can be immersed either into the sample or into the water in which the sample was placed. The specimens were strengthened via externally bonded reinforcement (EBR) and externally bonded reinforcement on grooves (EBROG) methods. After the concrete prisms had been subjected to 200 and 500 freeze–thaw cycles, they were placed in the single shear test machine. During each test run, a tensile force was applied to the FRP composite while the concrete block was restrained from movement. The single shear test machine consisted of a hydraulic jack with a capacity of 400 kN that provided the required force for the single shear test. Moreover, a load-cell with a capacity of 50 kN was used to measure the force applied to the specimens. In the current investigation, the specimens were subjected to a quasi-static loading of 2 mm/min in accordance with ASTM D3039/D3039M. The results of PIV measurements revealed that, compared with the specimens strengthened via the EBR method, the EBROG-strengthened specimens exhibited considerably enhanced bond performance. When subjected to 200 and 500 freeze–thaw cycles, the EBR-strengthened specimens experienced a 3% and 9% decrease in their bond strength, respectively; the EBROG-strengthened specimens experienced no decrease in bond strength and increases in the range of 7%–19% when subjected to 200 and 500 cycles, respectively.

Keywords

Subjects


[1] FIB, 2001. Externally bonded FRP reinforcement for RC structures. FIB Bulletin 14. International Federation for Structural Concrete.
[2] Kaiser, H., 1989. Bewehren von stahlbeton mit kohlenstoffserverstarkten epoxiharzen. Ph.D. thesis, Diss ETH Nr. 8918. EMPA, Zurich, Switzerland.
[3] Cho, K., S.Y. Park, S.T. Kim, J.R. Cho, and B.S. Kim, 2013. Freeze-Thaw Effect on Coarse Sand Coated Interface between FRP and Concrete Engineering. 5: 807-815.
[4] Green, M.F., K.A. Soudki., and M.M. Johnson, 1997. Freeze–thaw behaviour of reinforced concrete beams strengthened by fibre-reinforced sheets. Proceedings of the Annual Conference of the Canadian Society for Civil Engineering, Sherbrooke, Qué.pp. 31–39.
[5] H. Toutanji, P. Balaguru, Durability characteristics of concrete columns wrapped with FRP tow sheets. 1998 Materials Science Journal of Materials in Civil Engineering, DOI:10.1061/(ASCE)0899 1561(1998)10:1(52).
[6] Green, M.F., Dent, A.S., and Bisby, L.A. 2003. Effect of freeze–thaw cycling on the behavior of reinforced concrete beams strengthened in flexure with fiber reinforced polymer sheets. Civil Engineering. 30: 1081–1088.
[7] Chajes, M.J., T.A. Thomson, J. Farschman and A. Cory. 1995. Durability of concrete beams externally reinforced with composite fabrics. Construction and Building Materials, 9(3).
[8] Mohammadi, M. 2018. Environmental effects on the debonding of FRP-to-concrete surface using EBROG and EBR techniques Ph.D. thesis, Iran, Tabriz.
[9] Mostofinejad, D., and Hajirasouliha. M.J. 2013. Effect of concrete strength and groove dimension on performance of grooving method to postpone debonding of FRP sheets in strengthened concrete beams. IJST. Transactions of Civil Engineering. 37(C2): 219-232.
[10] Mostofinejad, D., and Moghaddas, A. 2014. Bond efficiency of EBR and EBROG methods in different flexural failure mechanisms of FRP strengthened RC beams. Construction and Building Materials. 54: 605–614.
[11] Mostofinejad, D., and Tabatabaei, A. 2013. Experimental study on effect of EBR and EBROG methods on debonding of FRP sheets used for shear strengthening of RC beams. Composites: Part B. 45(1): 1704–1713.
[12] Mostofinejad, D., and Shameli, S.M. 2013. Externally bonded reinforcement in grooves (EBRIG) technique to postpone debonding of FRP sheets in strengthened concrete beams. Construction and Building Materials. 38: 751–758.
[13] Mostofinejad, D., Shameli, S.M., and Hosseini, A. 2012. Experimental study on the effectiveness of EBROG method for flexural strengthening of RC beams,” Proc. Proceedings of sixth international conference on FRP composites in civil engineering, Rome, Italy.
[14] Mostofinejad, D., and Mahmoudabadi, E. 2010. Grooving as Alternative Method of Surface Preparation to Postpone Debonding of FRP Laminates in Concrete Beams. Journal of Composites for Construction. 14(6): 804-811.
[15] Hosseini, A., Mostofinejad, D., Hajialilue-Bonab, M. 2014. Displacement and strain field measurement in steel and RC beams using particle image velocimetry. J Eng Mech. 140 (11).
[16] Hosseini, A., and Mostofinejad, D. 2013. Experimental investigation into bond behavior of CFRP sheets attached to concrete using EBR and EBROG techniques. Composites Part B. 51: 130–139.
[17] ASTM C310-71. 1971. Standard test method for resistance of concrete to freezing and thawing. American Society for Testing and Materials. West Conshohocken.PA. ASTM International.
[18] Arefian. B., and Mostofinejad, D. 2021. Experimental Investigation and Modeling of FRP–Concrete Joint Bond Strength Based on Failure Depth. American Society of Civil Engineers (ASCE), 25(6): 0402105
[19] Adrian R. J. 1991. Particle-imaging methods for experimental fluid mechanics. Annu. Rev. Fluid Mech. 23(1): 261–304.
[20] White, D. J., Take, W. A., and Bolton, M. D. 2003. Soil deformation measurement using particle image velocimetry (PIV) and photogrammetry. Ge´otechnique. 53(7): 619–631.