Comparison of seismic behavior of steel moment frames equipped with linear and nonlinear viscosity dampers under near-fault earthquakes

Document Type : Original Research

Authors
1 Assistant Professor, Civil Engineering Department, Birjand University of Technology, Birjand, Iran
2 Assistant Professor, Faculty of Technology and Mining, Yasouj University, Choram, Iran
3 M.Sc. of Structural Engineering, Civil Engineering Department, Beat Institute of Higher Education, Kerman, Iran
Abstract
The displacement-based design method in structural design codes, in which displacement is considered a criterion for evaluating the structure, has been accepted due to the dependence of failure on displacement more than forces, overcoming the inherent shortcomings of force-based design methods. On the other hand, different levels and states can be defined concerning structures' performance. In the functional state of immediate occupancy, the relative lateral displacement due to cracking or plastic behavior does not remain in the structure. The structural members' stiffness and strength do not change fundamentally, and microscopic cracks are created in the structural members and façade. In the second case, i.e., life safety, some stiffness, and strength will be lost in all classes, relative deformation due to plastic behavior in the structure will be observed, and the risk of loss of life will be slightly higher. At the performance level, the collapse threshold remains in the members of structures of low stiffness and strength to withstand lateral loads, but the columns and load-bearing walls maintain their function, the relative deformations are high, and the structure is likely to collapse due to aftershocks. Due to decreased energy caused by earthquakes, dampers with passive control systems are installed in certain parts of the structure and absorb a relatively large part of the energy entering the structure under different mechanisms, and as a result, the structure does not suffer severe damage. After the Northridge and Kobe earthquakes, extensive laboratory studies were conducted to strengthen and increase the joints' ductility, and many modified joints were proposed. Extensive applied structural studies have been conducted on dampers' seismic behavior as one of the advanced tools of passive structural control systems due to earthquake energy dissipation. This work compares the effects of linear and nonlinear viscous dampers on the seismic behavior of 3, 9, and 20-stories steel moment frames, and the structural seismic responses are discussed. In linear dampers, the axial force is obtained by multiplying the damping coefficient ratio at the relative speed of the damper's two ends, and in the nonlinear state, the relative speed of the damper is between 0.2 and 1, in which 0.25 is used in the current study. The results showed that viscous dampers' implementation generally reduced the responses and decreased the structural damage during the earthquake. Absolute displacement of structural models in nonlinear dampers compared to linear ones has decreased with an increasing number of stories, but for maximum relative displacement with the increasing number of stories, nonlinear dampers had a more negligible effect. Due to the hysteresis extracted, nonlinear dampers in short and intermediate structures have more energy loss, which is significantly reduced in high damping structures. The plastic hinge distribution for these dampers has eliminated the failure LS at the life safety performance level. The base shear of 3, 9, and 20 story frames with a nonlinear damper is significantly reduced compared to a linear damper and shows the nonlinear damper's positive effect, especially on high-rise structural frame models.

Keywords

Subjects


1. Jeary A.P. 1996 The description and measurement of nonlinear damping in structures. Journal of Wind Engineering and Industrial Aerodynamics, 59(2-3), 103-114.
2. Ras A., & Boumechra N. 2014 Study of nonlinear fluid viscous dampers behaviour in seismic steel structures design. Arabian Journal for Science and Engineering, 39, 8635–8648.
3. Martinez-Rodringo M., & Romero M.L. 2003 An optimum retrofit strategy for moment resisting frames with nonlinear viscous dampers for seismic applications. Journal of Engineering Structure, 25(7), 913-925.
4. Altieri D., Tubaldi E., De Angelis M., Patelli E., & Dall'Asta A. 2017 Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems, Bulletin of Earthquake Engineering, 16, 963-982.
5. Silwal B., Michael R.J., & Ozbulut O.E. 2015 A super elastic viscous damper for enhanced seismic performance of steel moment frames. Engineering Structures, 105, 152-164.
6. Lin J.L., Liu T.H., & Tsai K.C. 2015 Real-valued modal response history analysis for asymmetric–plan buildings with nonlinear viscous dampers. Soil Dynamics and Earthquake Engineering, 77, 97-110.
7. Silwal B., Ozbulut O.E., & Michael R.J. 2016 Seismic collapse evaluation of steel moment resisting frames with super elastic viscous damper. Journal of Constructional Research, 126, 26-36.
8. Brodersen M.L., Ou G., Hogsberg J., & Shirley Dyke S. 2016 Analysis of hybrid viscous damper by realtime hybrid simulations. Engineering Structures, 126, 675-688.
9. Shariati A., kamgar R., & Rahgozar R. 2020 Optimum layout of nonlinear fluid viscous damper for improvement the responses of tall buildings. International Journal of Optimization in Civil Engineering, 10(3), 411-431.
10. Santos-Santiago M.A, Ruiz S.E., & Valenzula-Beltrán F. 2020 Influence if higher modes of vibration on the seismic response of building with linear and nonlinear viscous dampers. Journal of Earthquake Engineering, 1-23.
11. Kookalani S., Shen D. 2020 Effect of fluid viscous damper parameters on the seismic performance. Journal of Civil Engineering and Materials Application, 4(3): 141-153.
12. Salehi S., Ghobadi M.S. 2020 Seismic resilient bracing structure equipped with hybrid device at base. Soil Dynamic and Earthquake Engineering, 138.
13. Pineda A.C., Amortegui L.F., & Chesi C. 2019 Use of viscous fluid dampers for the improvement of the seismic response of RC structures. Vibroengineering Procedia, 23, 87-92.
14. Rezvani F.H., Yousefi A.M., & Ronagh H.R. 2015 Effect of span length on progressive collapse behaviour of steel moment resisting frames. Structures, 3, 81-89.
15. Esmaeilabadi R., & Bahar O. 2017 Improving performance of the direct displacement based design method with improving yield displacement estimation of steel MR frames. Journal of Structural and Construction Engineering, 4, 53-68. (in Persian).
16. FEMA-273. 1997 NEHRP Guidelines for Seismic Rehabilitation of Buildings. Building Seismic Safety Council, FEMA, Washington, D.C.
17. Agrawel A.K. & Amjadian M. 2015 Seismic component devices. Department of civil and environmental engineering, The City College of the City University of New York, 160 Convent Ave., New York, NY 10031.
18. Federal Emergency Management Agency (FEMA). 2014 HAZUS-MH 2.1 Technical Manual: Earthquake Model. Washington, DC: FEM.
19. No, S., 2800 2005 Iranian Code of Practice for Seismic Resistant Design of Buildings, 4th Revision. Building and Housing Research Center, Iran.
20. American Institute of Steel Construction (AISC). 2010 AISC Seismic. Seismic provisions for structural steel buildings, Chicago.
21. PEER Strong Motion Database. http:/peer.berkeley.edu.
22. Ras A., & Boumechra N. 2016 Seismic energy dissipation study of linear fluid viscous dampers in steel structure design. Alexandria Engineering Journal, 55(3), 2821-2832.