An anti-windup robust PID controller based on H_∞ for structural vibration attenuation

Document Type : Original Research

Authors
1 Department of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz, Iran
2 Department of civil Engineering,Tabriz Branch, Islamic Azad University, Tabriz, Iran
3 Faculty of Civil Engineering, University of Tabriz, Tabriz, Iran
Abstract
Successful implementation of active control technology requires an appropriate control algorithm to calculate the adaptive control force required by the actuators. Smart structures represent a new engineering approach that integrates the actions of digital sensors, actuators and control circuit elements into a single control system that can respond adaptively to environmental stochastic changes in a useful manner. The mathematical model of the system is an estimation of its actual dynamic behavior. In general, this difference can have a significant effect on the performance and stability of the control system. One of the important issues in active control algorithms is the evaluation of the control systemchr('39')s robustness to model uncertainties and the actuator saturation. In this paper, a Developed Robust Proportional Integral Derivative controller with uncertainties in the structural stiffness parameter, the sensing noise and saturation windup of the saturation is introduced. the PID control force is obtained in such a way that the infinity norm of the closed loop system transfer function from disturbance inputs to target outputs becomes minimal. By considering the parametric uncertainty in the structural stiffness parameters and multiplicative unstructured uncertainty and the windup phenomenon in the actuator model and existence of noise in the velocity sensor, PID control scheme has been developed in the form of state space. The PID control gains by taking advantage of the Hinfinity mixed sensitivity minimization criterion, are obtained simultaneously by considering the effects of all vibration modes of the building in such a way that the infinity norm of the closed loop transfer function from exogenous inputs to the controlled outputs becomes minimal. To demonstrate the robust performance and stability of the proposed algorithm, the results of numerical simulations on a 4-story structure equipped with an active tuned mass damper are used. The obtained results show the robust performance and stability of the proposed robust PID control scheme in comparison with conventional PID and linear quadratic regulator (LQR) control algorithms, both in time and frequency domains. According to the mean values ​​of performance indices, in average 11 and 7% more reduction in J1 , 7 and 5% in J2 and 10 and 6% in J3 in the proposed robust PID in comparison with the LQR and common PID for three models subjected to far field selected earthquake records. And in average 17 and 10% more reduction in J1 , 12 and 8% in J2 and 11 and 8% in J3 in the proposed robust PID in comparison with the LQR and common PID for three models subjected to near field selected earthquake records. And J4 which related to amount of control effort, for the proposed robust PID, LQR and conventional PID are 1.3e-2, 9.1e-3 and 7.9e-3 in average for the three models subjected to far field and 4e-2, 2.4e-2 and 2.7e-2 subjected to near field selected earthquake records. The obtained results show the robust performance and stability of the proposed controller in the presence of structural stiffness uncertainties, actuator saturation and measurement noise.

Keywords

Subjects


[1] Keshtegar, B. and Etedali, S., 2016: Novel mathematical models based on regression analysis scheme for optimum tuning of TMD parameters. Journal of solid fluid mechanics, 6(4), 59-75. (In Persian).
[2] Mohebbi, M., Shakeri, K. & Majzoub, H., 2012: Genetic Algorithm Based Approach for Optimal Design of Multiple Tuned Mass Dampers (MTMDs) under Earthquake Excitation. Modares Civil Engineering journal, 12(1) (In Persian).
[3] Pourzeynali, S., Fallah, N., & Akbari, A. M., 2014: Experimental Analysis of the TMD Control of Building Vibrations against Earthquake Excitations. Journal of civil engineering, 25(2), 147-158. (In Persian).
[4] Katebi, J. & Shoaei-parchin, M., 2017: Design of optimal controller for structures using differential evolution algorithm. Modares Civil Engineering journal, 17(1), 179-191. (In Persian).
[5] Zhou, K. and Doyle, J.C., 1998: Essentials of robust control (Vol. 104). Upper Saddle River, NJ: Prentice hall.
[6] Zhang, H., Shi, Y. & Mehr, A.S., 2011: Robust static output feedback control and remote PID design for networked motor systems. IEEE Transactions on Industrial Electronics, 58(12), 5396-5405.
[7] Guclu, R., 2006: Sliding mode and PID control of a structural system against earthquake. Mathematical and Computer Modelling, 44(1-2), 210-217.
[8] Aguirre, N., Ikhouane, F. and Rodellar, J., 2011: Proportional-plus-integral semiactive control using magnetorheological dampers. Journal of Sound and Vibration, 330(10), 2185-2200.
[9] Etedali, S., Sohrabi, M.R. & Tavakoli, S., 2013: Optimal PD/PID control of smart base isolated buildings equipped with piezoelectric friction dampers. Earthquake Engineering and Engineering Vibration, 12(1), 39-54.
[10] Zamani, A.A., Tavakoli, S. & Etedali, S., 2017: Fractional order PID control design for semi-active control of smart base-isolated structures: a multi-objective cuckoo search approach. ISA transactions, 67, 222-232.
[11] Heidari, A.H., Etedali, S. & Javaheri-Tafti, M.R., 2018: A hybrid LQR-PID control design for seismic control of buildings equipped with ATMD. Frontiers of Structural and Civil Engineering, 12(1), 44-57.
[12] Mahmoodabadi, M.J. & Nejadkourki, N., 2020: Optimal fuzzy adaptive robust PID control for an active suspension system. Australian Journal of Mechanical Engineering, 1-11.
[13] Campo, P.J. & Morari, M., 1990: Robust control of processes subject to saturation nonlinearities. Computers & Chemical Engineering, 14(4-5), 343-358.
[14] Meisami-Azad, M., Grigoriadis, K.M. & Song, G., 2013: Anti-windup linear parameter varying control of structural systems with magneto-rheological dampers. Journal of Vibration and Control, 19(12), 1779-1794.
[15] Bui, H.L., Nguyen, C.H., Bui, V.B., Le, K.N. & Tran, H.Q., 2017: Vibration control of uncertain structures with actuator saturation using hedge-algebras-based fuzzy controller. Journal of Vibration and Control, 23(12), 1984-2002.
[16] Salloum, R., Moaveni, B. & Arvan, M.R., 2015: Identification and robust controller design for an electromechanical actuator with time delay. Transactions of the Institute of Measurement and Control, 37(9), 1109-1117.
[17] Zhou, K., Doyle, J. C. & Glover, K. 1996: Robust and optimal control. New Jersey: Prentice hall, 146.
[18] Huo, L., Song, G., Li, H., Grigoriadis, K. 2007: H_∞ Robust control design of active structural vibration suppression using an active mass damper. Smart materials and structures, 17(1), 015021.
[19] Åström, K. & Hägglund, T. 2005: Advanced PID Control. ISA, Research Triangle Park, NC, 76-80.
[20] Arfiadi, Y., & Hadi, M. N. S. 2001: Optimal direct (static) output feedback controller using real coded genetic algorithms. Computers & Structures, 79(17), 1625-1634.
[21] Ogata, K. 2002: Modern control engineering. 5th Edition, Pearson, Upper Saddle River, 583-585.