Experimental study of Concrete-filled steel tube (CFST) columns after Exposure to High Temperature

Document Type : Original Research

Authors
1 PhD Candidate
2 Assistant Professor
Abstract
Predicting the residual load-bearing capacity of damaged concrete-filled steel tube (CFST) columns exposed to fire, based on the effects of eccentricities, is a subject on which relatively little research has been done. This paper aims to present the results of a series of post-fire residual capacity tests for CFST columns with different cross sections (circular and square), under axial load, and different eccentricities in the event of a failure. In this experimental study, the influence of parameters such as cross-sectional shape, load eccentricity, slenderness and fire protective coating on the post-fire residual capacity of CFST sections was investigated. Based on the results of this study, the following conclusions were obtained in the scope of this research work:The results showed that eccentricity could be effective in reducing the residual capacity of the column, but the change in the amount of eccentricity cannot be as effective as reducing the residual capacity of the columns. The studies indicate that the residual capacity is significantly reduced by increasing the slenderness ratio. Therefore, in order to determine the residual capacity of the CFST columns under load eccentricity, a simplified equation for predicting the reduction factor was proposed, a comparison between the predicted and experimental results shows that there is a reasonably good agreement. The tests show that by increasing the temperature over a cross-section of CFST columns, the residual axial load capacity and the axial stiffness of the unprotected columns decreased significantly compared to the unheated columns. Comparison of the axial compressive capacity of CFST columns with square and circular have shown that for columns having the same concrete material, the circular column has slightly better structural post-fire behavior than the square column. To fire-protected sections, the effect of the cross-sectional shape on the residual strength is significant, relative to the unprotected sections is more. In fact, by comparing the temperature distribution on the surface of the circular and square sections, one can find that the maximum temperature distribution at the circular cross sections is less than the square cross sections. Therefore, with less degradation of the properties of the cross-sectional materials, the more residual load-bearing capacity is expected. Finally, based on the experimental results, the ability to predict the residual load-bearing capacity of the concrete-filled hollow tube columns after exposure to the ISO-834 standard fire as per the modified design method in Eurocode 4 for the fire and ambient conditions were evaluated. The investigation’s results showed that the simplified method of Eurocode 4, in the ambient temperature produced safe results for predicting residual resistance of CFST columns after fire exposure, under both concentric and eccentric loading conditions. This approach was considered as a conservative method, with the MPEs for concentric loads, as well as both concentric and eccentric loads as -5.51% and -3.06% lower than the prediction, respectively.

Keywords

Subjects


[1] Lawson, R.M. and Newman, G.M. 1990 Fire Resistant Design of Steel Structures - A Handbook to BS 5950: P a rt 8. SCI Publication, 80.
[2] Han LH, Huo JS, Wang YC. 2005 Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire. J Constr Steel Res;61(7):882–901.
[3] Han LH, Yang YF, Yang H, Huo JS. 2002 Residual strength of concrete-filled RHS columns after exposure to the ISO-834 standard fire. Thin-Wall Struct;40(12):991–1012.
[4] Han LH, Huo JS. 2003 Concrete filled hollow structural steel columns after exposure to ISO-834 standard fire. J Struct Eng;129(1):68.
[5] Faqi Liu, Hua Yang, Leroy Gardner, 2016 Post-fire behaviour of eccentrically loaded reinforced concrete columns confined by circular steel tubes. Journal of Constructional Steel Research 122:495-510.
[6] David I. Rush, Luke A. Bisby, Allan Jowsey, Barbara Lane, 2015 Residual capacity of fire-exposed concrete-filled steel hollow section columns. Engineering Structures, 100: 550–563.
[7] ISO. ISO 834: 1999 fire resistance tests-elements of building construction. Geneva, Switzerland.
] 8 X.H. Dai, D. Lam 2012 Shape effect on the behaviour of axially loaded concrete filled steel tubular stub columns at elevated temperature”, Journal of Constructional Steel Research 73: 117-127.
[9] M.D. O'Shea, R.Q. 2000 Bridge Design of circular thin-walled concrete filled steel tubes. J. Struct. Eng. 126(11):1295-1303.
[10] Han LH, Zhao XL, Yang YF, Feng JB. 2003 Experimental study and calculation of fire resistance of concrete-filled hollow steel columns. J Struct Eng, 129(3):346-356.
[11] Han LH, Yang H, Cheng SL. 2002 Residual strength of concrete filled RHS stub columns after high temperatures. Advances in Structural Engineering. 5(2):123–134.
[12] Wang Y.C. 2005 Performance of steel–concrete composite structures in fire. Engng Mater. 7:86–102.
[13] Han L.H. Huo J.S. 2003 Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard. Journal of Structural Engineering. 129 (1): 68–78.
[14] Han L.H. Huo J.S. Yang Y.F. 2002, Concrete-Filled HSS Columns after Exposure to the ISO-834 Standard Fire, Advances in Steel Structures, 1127-1135.
[15] Zhong Tao, Xing-Qiang Wang, Brian Uy, 2013 Stress-strain curves of structural steel and reinforcing steel after exposure to elevated temperatures. Journal of Materials in Civil Engineering 25 (9): 1306-1316.
[16] Faqi Liu, Leroy Gardner, Hua Yang, 2014 Post-fire behaviour of reinforced concrete stub columns confined by circular steel tubes. Journal of Constructional Steel Research. 102:82–103.
[17] CEN. BS EN 1: 2004-1-1994; Eurocode 4, 2009, design of composite steel and concrete structures – Part 1-1: general rules and rules for buildings. Brussels, Belgium.
[18] CEN. BS EN 2: 2005-1-1994: Eurocode 4, 2008, design of composite steel and concrete structures – Part 2-1: general rules – structural fire design. Brussels, Belgium.