Experimental investigation on mechanical properties of normal strength concrete containing crimped-end hooked steel and modified polymer fibers

Document Type : Original Research

Authors
1 Shahrood University of Technology
2 University of Mazandaran
Abstract
An undesirable failure mode of a reinforced concrete beam is shear mode. Low tensile strength of conventional concrete and brittle crushing due to shear failure in reinforced concrete beams can be improved by adding adequate percentage of steel fibers. The combination of high and low elasticity fibers is capable of arresting macro- and micro-cracks. In fact, the bridging action of fibers on crack faces causes a strong limitation on opening of the crack. This phenomenon improves the aggregate interlock on the crack faces which results in increasing the shear strength of the cracked section. In order to accurately study the pull-out characteristics of crimped-steel fibers with end hook and to compare the results with the behavior of hooked steel fibers and crimped steel fibers alone, an experimental study was conducted. Pull-out load versus slip was thoroughly investigated in 25 specimens and parameters such as maximum pull-out force and its associated slip were taken into account for comparison purposes. The results indicated that the crimped-steel fibers with end hook have better performance in pull out test. In fact, the post-peak behavior of this type of fiber shows a slight drop in carried load. This increases the area under the load-displacement curve in comparison with the others. It can be predicted that cementitious composites reinforced with crimped-steel fibers with end hook would be more ductile than those reinforced with other fibers. In addition, the effect of modified polymer fibers along with different amounts of crimped end hook steel fibers on the mechanical properties of conventional concrete such as compressive strength and indirect tensile strength was studied. The modified polymer fibers were added into the mixes for arresting micro-cracks. 45 specimens were made in 5 groups and the volume fraction of polypropylene fiber was kept constant (0.25%). The volume fraction of steel fibers were selected in three ranges of 0.5%, 0.75%, 1.0%. Also a mix was cast without any fibers to be used for comparison purposes. The results of this study showed that by adding 0.25% polypropylene fibers and 1.00% crimped end hook steel fibers, 27.5% and 66.7% increase in compressive strength and indirect tensile strength are observed compared to conventional concrete. In all cases, by adding steel fibers with polypropylene fiber in the mentioned percentages, the fibers can show desirable performance in post-cracking behavior. Finally, the criteria of ACI 318-2011 for using this fiber reinforced concrete (without shear reinforcement) as the minimum shear reinforcement was investigated. The test is based on ASTM C1609 and it is applicable to the sections of a beam when the applied shear is less than the concrete strength from one hand but, on the other hand, it is greater than the half of that. It was found that this requirements is met in all proposed fiber reinforced concretes. It can be concluded that in such sections the cementitious composites studied in this paper can be utilized without accompanying any stirrups. In fact, the ductility required by ACI 318-2011 in this area can be provided with steel fibers, rather than stirrups.

Keywords

Subjects


[1] Uygunoğlu, T. (2008). Investigation of microstructure and flexural behavior of steel-fiber reinforced concrete. Materials and structures, 41(8), 1441-1449.
[2] Shaikh, F. U. A. (2013). Review of mechanical properties of short fibre reinforced geopolymer composites. Construction and Building Materials, 43, 37-49.
[3] Mohammadi, Y., Singh, S. P., & Kaushik, S. K. (2008). Properties of steel fibrous concrete containing mixed fibres in fresh and hardened state. Construction and Building Materials, 22(5), 956-965.
[4] Yazıcı, Ş., İnan, G., & Tabak, V. (2007). Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC. Construction and Building Materials, 21(6), 1250-1253.
[5] Kuder, K. G., & Shah, S. P. (2010). Processing of high-performance fiber-reinforced cement-based composites. Construction and Building Materials, 24(2), 181-186.
[6] Balaguru, P. N., & Shah, S. P. (1992). Fiber-reinforced cement composites.
[7] Lau, A., &Anson, M. (2006). Effect of high temperatures on high performance steel fiber reinforced concrete. 36(9), 1698-1707.
[8] Vogel, H. M., & Svecova, D. (2012). Evaluation of Elastic Modulus for High-Strength Concrete. ACI Materials Journal, 109(3).
[9] Ezeldin, A., & Balaguru, P. (1989). Bond behavior of normal and high-strength fiber reinforced concrete. Materials Journal, 86(5), 515-524.
[10] Hassanpour, M., Shafigh, P., & Mahmud, H. B. (2012). Lightweight aggregate concrete fiber reinforcement–a review. Construction and Building Materials, 37, 452-461.
[11] Barros, J. A., & Sena-Cruz, J. (2001). Fracture energy of steel fibre reinforced concrete. Journal of Mechanics of Composite Materials, 8(1), 29-45.
[12] Ghavami, K. (2005). Bamboo as reinforcement in structural concrete elements. Cement and concrete composites, 27(6), 637-649.
[13] Bentur, A., & Mindess, S. (1990). Fiber Reinforced Cementitious Composites,‖ Elsevier Applied Science. London and New York.
[14] Patel, P.A., Desai, A.K., Desai, A.J. (2012) . “Evaluation of Engineering Properties for Polypropylene Fiber Reinforced Concrete”. International Journal of Advanced Engineering Technology, 31 42-45.
[15] Banthia, N. and Gupta, R., (2006) . “Influence of Polypropylene fiber geometry on plastic shrinkage cracking in concrete”. Cement and Concrete Research. 367 1236-1267. doi: 10.1016/j. cemconres. 2006.01.010.
[16] Köksal, F., Altun, F., Yiğit, İ., & Şahin, Y. (2008). Combined effect of silica fume and steel fiber on the mechanical properties of high strength concretes. Construction and Building Materials, 22(8), 1874-1880.
[17] Song, P. S., Hwang, S., & Sheu, B. C. (2005). Strength properties of nylon-and polypropylene-fiber-reinforced concretes. Cement and Concrete Research, 35(8), 1546-1550.
[18] Sivakumar, A., & Santhanam, M. (2007). A quantitative study on the plastic shrinkage cracking in high strength hybrid fibre reinforced concrete. Cement and concrete composites, 29(7), 575-581.
[19] Toutanji, H. A. (1999). Properties of polypropylene fiber reinforced silica fume expansive-cement concrete. Construction and Building Materials, 13(4), 171-177.
[20] Yang, K. H. (2011). Tests on Concrete Reinforced with Hybrid or Monolithic Steel and Polyvinyl Alcohol Fibers. ACI Materials Journal, 108(6).
[21] Dawood, E.T., & Ramli, M. (2010). Development of high strength flowable mortar with hybrid fiber. Constr. Build. Mater. 24 (6), 1043–1050.
[22] Afroughsabet, V., & Ozbakkaloglu, T. (2015). Mechanical and durability properties of high-strength concrete containing steel and polypropylene fibers. Construction and building materials, 94, 73-82.
[23] Yazıcı, Ş., İnan, G., & Tabak, V. (2007). Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC. Construction and Building Materials, 21(6), 1250-1253.
[24] Banthia, N., Majdzadeh, F., Wu, J., & Bindiganavile, V. (2014). Fiber synergy in Hybrid Fiber Reinforced Concrete (HyFRC) in flexure and direct shear. Cement and Concrete Composites, 48, 91-97.
[25] Ramezanianpour, A. A., Esmaeili, M., Ghahari, S. A., & Najafi, M. H. (2013). Laboratory study on the effect of polypropylene fiber on durability, and physical and mechanical characteristic of concrete for application in sleepers. Construction and Building Materials, 44, 411-418.
[26] Qian C.X., and Stroeven, P., (2000). “Development of Hybrid Polypropylene-Steel Fiber Reinforced Concrete”. Cement and Concrete Research. 301 63-69.
[27] ASTM C114. Annual Book of ASTM Standards. Philadelphia, PA: ASTM; 2012.
[28] ASTM D2419, Standard test method for sand equivalent value of soils and fine aggregate, Annual Book of ASTM Standards, 2002.
[29] ASTM C33. Standard specification for concrete aggregates. Annual Book of ASTM Standards; 2004.
[30] 211.4R-08. Guide for Selecting Proportions for High-Strength Concrete Using Portland Cement and Other Cementations Materials. ACI 211 on high strength concrete; 2008.
[31] ASTM C 143/C 143M-98, (1998). Standard Test Method for Slump of Hydraulic Cement Concrete.
[32] ASTM C39. Standard test method for compressive strength of cylindrical concrete specimens. Annual Book of ASTM Standards; 2004.
[33] ASTM C496. Standard test method for splitting tensile strength of cylindrical concrete specimens. Annual Book of ASTM Standards; 2004.