[1] Koehler. E.P, Fowler D.W, (2007)ICAR Project 108: Aggregates in Self-Consolidating Concrete,.
[2] Nguyen, T.L.H., Roussel, N., Coussot, P. (2006). “Correlation between L-box test and
rheological parameters of a homogenous yield stress fluid,” Cement and Concrete Research, 36,1789-1796.
[3] Sleiman H, Perrot A, Amziane S (2010) A new look at the measurement of cementitious paste setting by Vicat test.Cem Concr Res 40:681–686.
[4] Pierre A, Perrot A, Picandet V, Guevel Y, “ Cellulose ethers and cement paste permeability”,Cement and Concrete Research Volume 72, June 2015, Pages 117-127.
[5] Hamed Layssi, Pouria Ghods, Aali R. Alizadeh, and Mustafa Salehi .” Electrical Resistivity of Concrete Concepts, applications, and measurement techniques “. Article in Concrete International • May 2015.
[6] ASTM, Standard test method for time of setting of concrete mixtures by penetration resistance, in C. 2005, American Society of Testing and Materials,ASTM-C403.
[7] Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle , ASTM Designation: C -191.
[8] Standard Test Method for Time of Setting of Hydraulic Cement Mortar by Modified Vicat Needle , ASTM Designation: C – 807.
[9] Michelsen, S., Beitrag zur bindezeit bsestimmung. Zement, 1933. 22(3): p. 457-461.
[10] Gu, P., et al., Investigation of the retarding effect of superplasticizers on cement hydration by impedance spectroscopy and other methods. Cement and concrete research, 1994. 24(3): p. 433-442.
[11] Torrents, J., J. Roncero, and R. Gettu, Utilization of impedance spectroscopy for studying the retarding effect of a superplasticizer on the setting of cement. Cement and Concrete Research, 1998. 28(9): p. 1325-1333.
[12] McCarter, W., et al., Characterization and monitoring of cement-based systems using intrinsic electrical property measurements. Cement and Concrete Research, 2003. 33(2): p. 197-206.
[13] Topçu, İ.B., T. Uygunoğlu, and İ. Hocaoğlu, Electrical conductivity of setting cement paste with different mineral admixtures. Construction and Building Materials, 2012. 28(1): p. 414-420.
[14] Wei, X. and Z. Li, Early hydration process of Portland cement paste by electrical measurement. Journal of materials in civil engineering, 2006. 18(1): p. 99-105.
[15] Whittington, H., J. McCarter, and M. Forde, The conduction of electricity through concrete. Magazine of concrete research, 1981. 33(114): p. 48-60.
[16] Li, Z., X. Wei, and W. Li, Preliminary interpretation of Portland cement hydration process using resistivity measurements. ACI Materials Journal, 2003. 100(3).
[17] Xiao, L.-z., Z.-j. Li, and X.-s. Wei, Selection of superplasticizer in concrete mix design by measuring the early electrical resistivities of pastes. Cement and Concrete Composites, 2007. 29(5): p. 350-356.
[18] Mancio, M., et al., Instantaneous Determination of Water-Cement Ratio of Fresh Concrete. ACI Materials Journal, 2010. 107(6).
[19] Standard Test Method for Slump Flow of Self-Consolidating Concrete , ASTM C1611.
[20] Standard Test Method For Passing Ability Of Self Consolidating Concrete by J-RING , ASTM C-1621 .
[21] Eric P. Koehler , David W. Fowler , ” DEVELOPMENT OF A PORTABLE RHEOMETER FOR FRESH PORTLAND CEMENT CONCRETE “ , ICAR Report 105-3F, ICAR 105: Measuring the Workability of High Fines Concrete, August 2004.
[22] Self Compacting Concrete European Project Group, “The European Guidelines for Self-Compacting Concrete,” BIBM, CEMBUREAU, EFCA, EFNARC and ERMCO, 2005, p. 63.
[23] ACI 238.R-8 , Report on measurements of workability and rheology of fresh concrete.
[24] Salem, T.M., Electrical conductivity and rheological properties of ordinary Portland cement–silica fume and calcium hydroxide–silica fume pastes. Cement and concrete research,