Improving the seismic performance of new composite multi-story moment frames in comparison with conventional concrete moment frames

Authors
Abstract
In recent years, composite frames that are consist of reinforced concrete column and steel beam, have been attended by researchers due to their economic efficiency as well as their effect on improving the behavior of tall structures. In such frames, using of concrete in columns, due to the compressive strength of concrete and using of steel in the element of beam, due to high tensile strength of steel, result in reduction of elements section and structure weight and also improving its performance. Previous studies have shown that the most important issue in these frames is their connections. Moment connections of such frames are through-beam-type and through-column-type connections. Details of these connections should be in such a way that prevent the formation of plastic hinge in panel zone, and besides, has adequate ductility. Most studies, so far, have been done on the details of through-beam-type‎ and little researches have been done on the plans of through-column-type connection. Nonetheless, determination of beam-column connection with appropriate seismic performance and also force transmission mechanism is necessary. In this study, amount of the effect of proposed composite connection consist of through-‎reinforced concrete column and attached steel beam with peripheral diaphragms and inter plates, on the improvement of the behavior of composite moment frames than conventional concrete frames has been investigated ‎ that the sample of this connection has been made and tested, laboratorial, by the authors. The survey has been conducted on the amount of displacement and drift of frame’s stories and also on the loading capacity, ductility and energy absorption of frames‎. For this purpose, firstly, a composite frame of one story-one span with the proposed connection has been modeled by two finite elements softwares called Abaqus and ‏SeismoStruct and the displacement control has been analysed under pushover lateral loading, and its results have been compared with the results of reference concrete frame. To ensure of the accuracy of the modeling that has been done, load-displacement curve that is the resultant of the connection model of Abaqus and ‏SeismoStruct, has been compared with experimental results. Then, three concrete frames and three composite moment frames with four, seven and ten stories, with four 5-meters spans, 3 meters in height of each story, that had been selected from the meddle frame of a construction with dimensions of 20 meters by 20 meters in plan, and had been designed for area with high seismic risk, were modeled ‎‏by SeismoStruct software, and were analysed under mentioned loading. The results showed appropriate performance of composite moment frames which are consist of mentioned connection, especially in frames with high number of stories. In this study, the drift of the frame and the relative drift of stories, have been reduced in composite moment frames than conventional concrete frames. Moreover, using the proposed composite connections in composite frames has resulted in the increase of the loading capacity of the frame so that the maximum of force that is tolerated by composite frames with 1,4,7 and 10 stories has been increased, respectively, by 59%, 49%, 67% and 46% than concrete frames. In addition, ductility of composite frames with 1,4,7 and 10 stories has been increased, respectively, by 65%, 50%, 37% and 30% than ‎concrete frames with similar number of stories.‎ The results have indicated the increase in initial and final stiffness of composite frames than concrete frames, in average, by 62% and 10%, respectively. Furthermore, a 116% increase in the energy absorption of composite frames than concrete frames has been observed.

Keywords

Subjects


[1] razzaghi J., Pourzeynali S., Hosein Nezhad A. & Hosseini A. 2006 Analyze of RCS composite frames reliability. 2nd National Congress on Civil Engineering. Iran University of Science & Technology. (In Persian)
[2] Sheikh T.M., Deierlein G.G., Yura J.A. & Jirsa J.O. 1989 Beam-Column moment connections for composite frames: Part 1. structural engineering, ASCE, 115(11), 2858-2876.
[3] Sheikh T.M., Deierlein G.G., Yura J.A. & Jirsa J.O. 1989 Beam- Column moment connections for composite frames: Part 2. structural engineering, ASCE, 115(11), 2877-2896.
[4] Baba N. & Nisimura Y. 2000 Stress transfer on through beam type steel beam-reinforced concerete column joints ,proc. of 6th ASCCS conference.
[5] Bugeja M.N., Bracci J.M. & Moore W.P. 2000 Seismic behavior of composite RCS frame systems. structural engineering ,ASCE , 126(4), 429-436.
[6] Parra- montesinos G., Wight J.K. 2000 Seismic response of exterior RC column to steel beam connections. structural engineering, ASCE, 126(10), 1113-1121.
[7] Nishiyama I., Itadani H., & Sugihiro k. 1997 3D beam-column connection (joint panel) tests on RCS. 4th JTCC meeting.
[8] Kim k., Noghuchi H. 1997 An analytial study on the shear strength of RCS joints. 4th JTCC meeting.
[9] Cordova P. & Deierlein, G.G. 2005 Validation of the seismic performance of composite RCS framed: full-scale testing, analytical modeling and seismic design. Stanford University, Department of civil and environmental engineering, Report No.155.
[10] Gregor D., Wald F. 2002 Component model for steel to concrete joints. Czch technical university in prague.
[11] Steele j.p., Bracci, J.M. 2003 Composite RCS space frame systems: Constructability and Performance. Technical report CDCI-03-02, Center for design and construction integration, Department of civil engineering, Texas A&M University.
[12] Parra- montesinos G., Liang X. 2004 Seismic behavior of reinforced concrete column-steel beam subassemblies and frame systems. structural engineering, ASCE, 130(2), 2004, pp. 310-319.
[13] Nguyen X,H., Nguyen Q.H., Le D.D. 2017 Experimental study on seismic performance of new RCS connection. Structures, 9, 53-62.
[14] Hosseini A., Razzaghi J., Ranjbar M. & Madandoost R. 2006 Ivestigating the seismic behavior of concrete and steel composite moment frames(RCS). 2nd International Conference on concrete and development, Tehran. (In Persian)
[15] Habashizadeh M., Chenaghlou M.R., Abedi K. & Afshin H. 2014 Numerical modeling of RCS frames and effect of joint behavior on the overall response. Civil and environmental engineering, 44(2), 11-19. (In Persian)
[16] Farahmand Azar B., Ghaffarzadeh H., & Talebian N. 2013 Seismic performance of composite RCS special moment frames. KSCE Journal of civil engineering 17(2), 450-457.
[17] Alizadeh S., Attari N.K.A., TaghiKazemi M. 2015 Experimental investigation of RCS connections performance using self-consolidated concrete. constructional steel research 114, 204-216.
18] Mirghaderi S.R., BakhshayeshEghbali N., & Ahmadi M.M. 2016 Moment-connection between continuous steel beams and reinforced concrete column under cyclic loading. constructional steel research 118, 105-119.
[19] Heydarian N. 2012 Experimental investigation of effect perimeter diaphragm on hybrid connection of RC column and steel beam. MSc thesis. Semnan university, Faculty of civil engineering. .(In Persian)
[20] Sharbatdar M.K., Heydarian N., & Haghighat, A. 2016 Experimental investigation of perimeter diaphragm and internal plate effect on hybrid connection of steel and concrete structural elements. Sharif, civil engineering, Volume 32.2,Issue 3.1, 97-105.(In Persian)
[21]Hemmati A. 2013 Investigation of Flexural Behavior of HPFRCC Beams and Frames. PhD Thesis, Department of Structural Engineering, Semnan University. (In Persian)
[22] Tasnimi A.A. & Salimi M. 2007 The effect of concrete confinement on the behavior factor of concrete structures. Modares civil engineering, 19(1). (In Persian)
[23] Kim K.D., Engelhardt M.D.2002 Monotonic and cyclic loading models for panel zones in steel moment frams. constructional steel research 58, 605-635.
[24] Haghighat A. 2013 Numerical investigation of perimeter diaphragm effect in hybrid steel beam- concrete column connections and hybrid frames performance. 2013 M.Sc thesis. Semnan university, Faculty of civil engineering. (In Persian)
[25] Applied technology council 555 Twin Dolphin drive,1996 Seismic evaluation and retrofit of concrete buildings. ATC 40 , volume 1,Redwood city , California , report No. SSC 96-01