Application of Elliptic Slits for Development of Slit Damper in Beam-to-Column Connection

Authors
1 University of Sistan and Baluchestan
2 Assistant Professor, University of Sistan and Baluchestan
Abstract
The rigid steel connections were suffered severe damage because of low rotational capacity during earthquakes. Hence many investigations have been performed on the connections of steel structures. In order to prevent brittle failure of connections and damage of main structural members, steel slit dampers with uniform strip width are used in the beam-to-column connections. Slit damper is a plate or a standard section with a number of slits in the web. The remaining strips in the web of damper, dissipate the seismic energy with inelastic deformation absorption and also prevent seismic energy transmission to the main structural members. No special fabrication technique was involved in the slit dampers, thus the device can be easily used in practice. To verify the accuracy of finite element modeling, the obtained results of ABAQUS finite element software were compared with an experimental study done by Oh et al (2009). The analytical results have a good agreement with experimental ones and the average error is about 2%. According to the analyses performed in the ABAQUS, using steel slit dampers with uniform strip width is resulted in stress concentration at the ends of the damper strips, unbalanced distribution of Von-Mises stresses along the strips length and low participation of middle parts of slit damper strips in the energy dissipation. Therefore, to resolve these problems and energy-absorbing area rise in the end parts of strips, elliptic slit damper is proposed and compared with the previous investigated slit damper. Slits dimensions of elliptic slit damper are calculated as such that both of present and previous slit dampers have the same weight. The objective of this paper is to improve the seismic performance of steel slit dampers. Nonlinear analyses are carried out in the beam-to-column connections equipped with slit dampers. Effects of geometrical and material nonlinearity are considered in the analyses. Nonlinear characteristics of steels are defined with stress-strain curves. Bilinear stress-strain curves are used for all steel parts except the slit damper which is defined with completed stress-strain curve. Plasticity behavior of steel materials is based on the Von-Mises yielding criteria. Loading protocol recommended by FEMA-350 is used for cyclic analyses. All parts of connection are modeled using shell elements except the split-T plates and the upper plate of slit dampers which are modeled using solid elements. The results of connections analysis under cyclic loading show that the proposed elliptic slit damper causes better distribution of stresses along the damper strips, better hysteresis performance and increase the amount of energy dissipation in the beam-to-column connection. Also elliptic slit damper leads to strength and ductility increment in the connection. Additionally, it is concluded that in the proposed elliptic slit damper compared to the slit damper with uniform strip width, the energy dissipation and the maximum plastic rotation of connection increase about 99.6 and 26.8%, respectively.

Keywords


] Saffari, H., Hedayat, A.A., Poorsadeghi Nejad, M., "Post-Northridge connections with slit dampers to enhance strength and ductility", Journal of Constructional Steel Research, Vol. 80, 2013, pp. 138–152.
[2] Wada, A., Huang, Y.H., Yamada, T., Ono, Y., Sugiyama, S., Baba, M., Miyabara, T., "Actual size and real time speed tests for hysteretic steel damper", Proceedings of Stessa, Vol. 97, 1997, pp. 778-785.
[3] Lee, M.-H., Oh, S.-H., Huh, C., Oh, Y.-S., Yoon, M.-H., Moon, T.-S., "Ultimate energy absorption capacity of steel plate slit dampers subjected to shear force", Steel Structures, Vol. 2, 2002, pp. 71-79.
[4] Benavent-Climent, A., "Development and application of passive structural control systems in the moderate-seismicity mediterranean area", The 14th World Conference on Earthquake Engineering, Beijing, 2008.
[5] Chan, R., Albermani, F., "Experimental study of steel slit damper for passive energy dissipation", Engineering Structures, Vol. 30, 2008, pp. 1058–1066.
[6] Oh, S.-H., Kim, Y.-J., Ryu, H.-S., "Seismic performance of steel structures with slit dampers", Engineering Structures, Vol. 31, 2009, pp. 1997-2008.
[7] Ghabraie, K., Chan, R., Huang, X., Xie, Y.M., "Shape optimization of metallic yielding devices for passive mitigation of seismic energy", Engineering Structures, Vol. 32, 2010, pp. 2258-2267.
] 8[ خوشنودیان، ف.، کیانی، م.، "بررسی عملکرد میراگر فولادی شکافدار (SSD) در سازه های فولادی با سیستم قاب خمشی ویژه"،  اولین همایش ملی سازه- زلزله- ژئوتکنیک، مازندران، بابلسر، 1389.
[9] Karavasilis, T.L., Kerawala, S., Hale, E., "Hysteretic model for steel energy dissipation devices and evaluation of a minimal-damage seismic design approach for steel buildings", Journal of Constructional Steel Research, Vol. 70, 2012, pp. 358–367.
] 10[ توحیدی مقدم، و.، سعید منیر، ح.، "بررسی عملکرد میراگر شکافدار لوله ای تحت بارگذاری لرزه ای"، دومین کنفرانس ملی مدیریت بحران، تهران، 1391.
] 11[ توحیدی مقدم، و.، سعید منیر، ح.، "کاربرد میراگر فولادی شکافدار لوله‌ای (CSSD) در سازه های قاب خمشی فولادی"، سومین کنفرانس ملی زلزله و سازه، کرمان، 1391.
] 12[ زهرائی، س.م.، امین‌دهقان، ا.، "بررسی عملکرد یک سیستم میراگر فلزی نوین در بهبود رفتار لرزه‌ای مهاربندهای هم محور"، دومین کنفرانس ملی مدیریت بحران، تهران، 1391.
] 13[ زهرائی، س.م.، امین‌دهقان، ا.، "ارزیابی شکل پذیری و استهلاک انرژی میراگر فلزی نوین لوله در لوله برای کاربرد در قاب های فولادی مهاربندی شده"، دومین کنفرانس ملی مدیریت بحران، تهران، 1391.
[14] Koken, A., Koroglu, M.A., "Waste rubber damper using on steel beam to column connection", International Journal of Arts & Sciences, Vol. 5, 2012, pp. 217–222.
] 15[ مشتاق، ا.، شیدایی، م.ر.، توحیدی مقدم، و.، "کاربرد میراگر شکافدار لوله‌ای فولادی (CSSD) بر رفتار خرابی شبکه های تخت دو لایه فضاکار و ارزیابی خرابی پیشرونده در آنها"، سومین کنفرانس ملی زلزله و سازه، کرمان، 1391.
] 16[ مشتاق، ا.، توحیدی مقدم، و.، سعیدمنیر، ح.، "مطالعه و بررسی گسیختگی پیشرونده بر روی قاب های مقاوم سازی شده با میراگر شکافدار لوله ای"،  دومین کنفرانس ملی سازه- زلزله- ژئوتکنیک، مازندران، 1391.
[17] ABAQUS, Version9.10, Dassault Systemes., USA, 2010.
[18] Oh, S.-H, "Seismic design of energy dissipating multi-story frame with flexible-stiff mixed type connection", Ph.D. Thesis, Tokyo University, 1998.
[19] FEMA 350., "Recommended Seismic Design Criteria for New Steel Moment Frame Buildings", SAC Joint Venture, 2000