Suggested Estimating Method for Hydrodynamic Pressure to Seismic Design of Hydraulic Structure Gates in Adjacent To Dam Reservoir

Authors
Tarbiat Modares University
Abstract
Abstract:
No dam could be safely designed without functionality dependence on reliable performance of a number of appurtenant structures.
Gates are the main appurtenant structures responsible for controlling water flow from the reservoir. Earthquakes induce acoustic and surface waves in the reservoir and cause hydrodynamic pressure on the adjacent gates. Hydrodynamic pressures might surpass hydrostatic pressure on some locations of the dam upstream face. Some engineers use the hydrodynamic pressure solution concerning to axi-symmetric offshore and coastal structures for the design of such hydro-mechanical gates. Flexibility of these gates may magnify the hydrodynamic pressure due to severe generation of vibrations separate from the dam body itself even for those installed within the dam bodies. This statement reflects the design philosophy of secondary structures. Fundamental frequency of such gates are usually reduced due to the presence of infinite fluid in their vicinity. Therefore the study of their behavior is somehow complicated during the earthquake. Design regulations of hydraulic structures, demand the hydrodynamic pressure as a design action and usually admits its simple calculation from the Westergaard formula. In this article, by using floor response spectrum in gate level which is used to design the secondary systems and also the spectral acceleration parameter in gate level which is used based on predominant frequency of gate-reservoir, the common relation of gate design against hydrodynamic pressure has been corrected. Then a new non-dimension factor is suggested for sliding rectangular gates in different levels of dam body that is related to the performed analyses and log-normal distribution of data..
In general for various conditions the dimensionless coefficient of Westergaard formula changes from 0.875 to widely varying values between 0.25 to 2.5 when using the base acceleration. However when the spectral acceleration of the floor response spectrum is used for the fundamental frequency of gate-reservoir, this coefficient is more precisely determined for vertical rectangular gates.

Keywords


مراجع
[1]  ICOLD, Design and evaluation of appurtenant structures to seismic shaking, Bulletin 123, 1999.
[2]  Westergaard, H. M., “Dynamic water pressure on dams during earthquake” , Transactions of American Society of Civil Engineers, Vol 98, pp 418-433, 1933.
[3]  Chopra, A. K., “Hydrodynamic pressure on dams during earthquakes”, Proc, ASCE, Vol 93, No. EM6, 1967.
[4]  Chopra, A. K., “Simplified Evaluation of added mass for intake towers”, J. Struct. Eng. , ASCE, 115:1393-1412, 1989.
[5]  Kolkman, P. A., “Flow-Induced gate vibrations, Prevention of self excitation , computation of dynamic gate behavior and the use of medels”, Publication No.164, Delft Hydraulic Laboratory, Delf, The Netherlands, 1980.
[6]  Kojic, S. B., Trifunac, M. D., “Transient pressures in hydrotechnical tunnels during earthquakes”, Journal of Earthquake.Engineering and Structural Dynamics, Vol 16, pp. 523-539, 1988.
[7]  Seda-Sanabria, Y., Hall, R. L., Suarez, L. E., “Hydrodynamic study of the lmset wicket gate using a 1:25-scale model”, Journal of Mechanical Systems, Vol 12, No5, pp. 661-677, 1998.
[8]  Nugroho, W. S., Wang, K. and Hodking, R. J. et al., “Time dependent response of a floating flexible plate to the impulsively started steadily moving load”, Journal of Fluid Mechanics, 381:337-355, 1999.
[9]  Daniell, W. E.  & Taylor, C.A. “The seismic safety evaluation of a radial flood gate”, Proceeding ICOLD 20th Congress on Large Dams, IV, Q79-R9, pp. 123-132, 2000.
[10]  Wieland, M., “Hydrodynamic pressures”, Int. Water Power and Dam Construction, 20 September, 2005.
[11]  Hydraulic Gate and Penstock Association, Technical Standards for gates and Penstocks, Japanees Standards, 1996.
[12]  US Army Corps of Engineers, Vertical Lift Gates, Engineers Manual, 1110-2-2701, 30 November 1997.
[13]  Fenves, G., Chopra, A. K., “Effects of reservoir bottom absorption on earthquake response of concrete gravity dams”, Earthquake Eng. and Structural Dynamics, Vol 11, 1983.
[14]  Bustament, J. I. et al., “Water pressure on dams subjected to earthquakes” , Journal of Eng. Mech., ASCE, Vol 92, No. EM6, Oct, 1966.
[15]  Pani, P. K., Bhattacharyya, S.K., “ Fluid-structure interaction effects on dynamic pressure on of rectangular lock-gate”, Journal of Finite Element in Analysis and Design, Vol43, pp.739-748, 2007.
[16]  Pani, P. K., Bhattacharyya, S. K., “Hydrodynamic pressure on vertical gate considering  fluid-structure interaction”, Journal of Finite Element in Analysis and Design, Vol44, pp.759-766, 2008.
[17]  Pani, P. K., Bhattacharyya, S. K., “Finite element analysis of vertical rectangular plate coupled with an unbounded fluid domain on one side using a truncated far boundary”, Journal of Hydrodynamics, Vol21, No2, pp. 190-200, 2009.
[18]  Naeim, F., The seismic design Handbook, FirstEdition, VanNostrand Reinhold, Chapter 12, 1989.
[19]  Bayliss, A., Turkel, E., “Radiation boundary conditions for wave-like equations”, ICASE Report, 79-126, 1979.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
[20]   Sharan, S. K., “Finite element modeling of infinite reservoirs”, Journal of Eng. Mech., Vol.111, No12, Dec, 1985.