Estimation of Overstrength Factor for Steel Plate Shear Wall Structures

Author
University of Isfahan
Abstract
Steel plate shear walls are very effective lateral load resisting systems with high lateral stiffness and ductility capacity. Although there are valuable experimental data available for such systems, most of the current seismic codes (including Iran’s Std. 2800) provide none or limited design provisions for such structural systems. One of the important seismic performance parameters of the structures is “over-strength factor” which is implicitly or explicitly part of seismic design base shear formulation. Most of the available data on this factor are obtained from experimental research and therefore results are limited to low-rise structures and/or with reduced scaled structures. The main objective in this research is to assess the over-strength factor for the steel shear walls. A closed-form-solution is proposed for obtaining this factor based on plate-frame interaction. It was found that the over-strength factors obtained by this method are in line with available experimental data and analytical results obtained in this study.
In derivation of this closed form solution the following assumptions are made: 1) beam-to-column connection is rigid, 2) SPSW behaviour is affected by the interaction of the steel plate and its surrounding frame members, 3) the first storey, usually the soft storey, controls ductility and strength of the structure in general, 4) the beam remains rigid and the plastic hinges only form in the columns, 5) stresses due to the bending action in the plate do not interfere with the stresses due to buckling in the plate, 6) stress-strain relationship of the steel plate and the steel frame members are elastic-perfectly plastic.
The experiments on SPSWs used in this study were conducted in four major universities three of which in Canada and USA. The analytical model used in this study for finite element verification of the results is a three storey building that is adopted from a previous study on SPSW structures which was based on SAC buildings.
It was found that the overstrength factor of a multistorey SPSW structure can be estimated by that of only the first storey of that. Also the results for the overstrength factor are not that sensitive to the angle of tension field in the plate. Moreover, it was found that this factor decreases with a decrease of plate thickness and the yield stress of the plate.

Keywords


[1] صبوری، س، سیستم های مقاوم در برابر بارهای جانبی- مقدمه ای بر دیوارهای برشی فولادی، تهران،1380.
[2]  Sabouri-Ghomi, S., and Roberts, T.M. “Nonlinear dynamic analysis of steel plate shear walls including shear and bending deformations”, Engineering Structures, 14, (5), (1991), 309-317.
[3]  Sabouri-Ghomi S. Lateral load resisting systems: an introduction to steel shear walls, Anguizeh Publishing Ltd., Tehran, Iran, 2002.
[4]  Rahgozar M.A. and Humar J.L. “Accounting for overstrength in seismic design of steel structures” Canadian Journal of Civil Engineering, 25 (1998) 1-15.
[5]  Uang, C. M., "Establishing R (or Rw) and Cd factors for building seismic provisions" , ASCE, Journal of structural engineering, 117(1), (1991) 19-28.
[1]  abouri-Ghomi S., and Gholhaki M. “Ductility of thin plate shear walls” Asian Journal of civil engineering (Building and housing), 9 (2) (2008) 153-166
[2]  Sabouri-Ghomi, S. and Gholhaki, M., “Cyclic tests on two specimens of three-story ductile steel plate shear wall”, Report of Tests, Building and Housing Research Center (BHRC), (2006), 167 pages.
[3] صبوری، س و قلهکی، م. "آنالیز و طراحی برشی دیوارهای برشی فولادی شکل پذیر با استفاده از مدل اندرکنش ورق و قاب"، سومین کنگره ملی مهندسی عمران دانشگاه تبریز, دانشکده فنی مهندسی عمران، 1386.
[4]  Berman J.W., "Seismic behavior of code designed steel plate shear walls" Journal of Engineering Structures, 33 (2011), 230–244.
[5]     ANSYS® Academic Research, Release 14.0, Help System, Coupled Field Analysis Guide, ANSYS, Inc.