Farmaniyeh, Dibaji Shomali, Arghavan, No:21
Abstract: (9300 Views)
Providing mid-story stair slab to column hinge connection is practically difficult in concrete moment resisting frame structures. The problem is due to the fact that this connection is modeled as hinge connection in the modeling phase of structural analysis but in practice because of lack of proper detailing this is not fully satisfied and can lead to inappropriate column behavior and may affect the structural behavior as a whole. In this article, a simple hinge connection detailing based on shear-friction behavior has been proposed. This connection is based on the Iranian national building code and can provide the proper hinge connection in the mentioned joint.
Received: 2010/11/14 | Accepted: 2011/11/22 | Published: 2013/05/20