Abstract:   (10090 Views)
The steel-concrete composite beams are increasingly used in bridge and building construction in recent years. In this system, a shear connection between steel and concrete should be provided to effectively transfer the shear forces and to make the two materials act as a single unit. The mechanical shear connectors provide this means. They are the essential component of any composite beam system. Many studies have been performed on shear connectors and many different steel shapes have been suggested for connectors. The steel studs and channels are the most popular code accepted connectors. However, economic considerations continue to motivate the development of new products. Present knowledge of the capacity and behavior of the shear connectors are mainly limited to the data obtained from the push-out or beam tests with the latter being more expensive and accurate. Therefore, analytical procedures that can predict the nonlinear response and the capacity of the composite beams are necessary when the experimental resources are not available. In this study a three-dimensional FE model using the computer code ABAQUS is developed to simulate the push-out tests of angle shear connectors. The main objective of this study is to investigate the behavior and to find the ultimate strength of angle shear connectors in a solid slab. In order to obtain dependable results from the FE analysis, all components of the connection should be correctly modeled. There are four parts in this model: concrete slab, shear connector, steel beam and the rigid base. Because of symmetry, only a quarter of the push-out specimen is modeled.Nonlinear material and large displacement capability are employed. The load-slip behavior, capacity and maximum displacement at failure obtained from the finite element model were validated against available push-out test results. The results show the FEM can predict the capacity of the angle shear connectors with adequate precision. Using the FE model, a parametric study was conducted to evaluate the effect of variations in angle dimensions and concrete strength. The parametric study reveals that: • The capacity of angle connector increases with increasing concrete strength. • The Flange width has no measurable effect on angle connector capacity and its behavior. • The height of the angle has no considerable effect on load-displacement behavior of the connector. • The capacity of angle connector increases whereas the maximum slip decreases with increasing angle thickness. • The stress value is not constant along the angle length and it decreases from the center of the angle towards the edges. The shorter the length of the connector, the lower the stress change. Therefore, long angle shear connectors become ineffective. An equation is suggested to predict the angle effective length. Finally, an equation is proposed to predict the ultimate shear strength of the angle connectors.
Full-Text [PDF 926 kb]   (8066 Downloads)    
Article Type: Original Manuscript | Subject: --------
Received: 2014/01/14 | Accepted: 2015/08/12 | Published: 2015/09/23

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.