Volume 15, Issue 3 (2015)                   MCEJ 2015, 15(3): 171-182 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ghazali F, Salehi Neyshabouri S A A, Kavianpour M R. The effect of bottom outlet geometry changes on hydraulic characteristics of flow. MCEJ 2015; 15 (3) :171-182
URL: http://mcej.modares.ac.ir/article-16-10367-en.html
Abstract:   (17496 Views)
Outlet conduits are one of the important parts of dams. Due to the high flow rate and pressure drop, problems such as cavitation can affect these structures. Considering these problems, detailed design is necessary. Laboratory studies are usually carried out which are expensive, thus, numerical models for determining complex flow characteristics have attracted the attention of the designers. In this study, the numerical simulation of Jegin dam outlet conduit in south of Iran with the scale of 1:10 is provided and the results are verified by experimental information taken from physical model built and tested at Water Research Institute. Gate opening in this research is always 70% and the water head is the constant value of 38.6m. The research is focused on the intake gate and not the service one, so the service gate is always fully opened. FLUENT computer code is considered for the numerical model studies. In the numerical simulation the Finite volume mixture two phase flow scheme is used together with k–e turbulence model. The flow discharge and air supply from the air vent downstream of the gate is then computed by 3D numerical model for different channel geometries. Reasonable agreement between the numerical model and experimental results shows reliable performance of the numerical model. This study showed the ability of the numerical model to simulate the complex air water flow in high speed gated tunnels. This study also includes the effect of the height to width ratio of the conduit on flow discharge and aeration downstream of the gate. To do this, different numerical models are simulated among which the difference is the height to width ratio of the conduit. Height and width of the conduit are measured at the gate section and changes are applied in two cases of constant height (depth) and variable width, and constant width and variable height. Results show more aeration and more flow discharge while heightening and widening of the outlet. Flow discharge has also been determined as function of the height to width ratio of the conduit at gate section of the channels. One of the important results is that in comparison with the width changes, height changes of the channel affect hydraulic characteristics of flow more and the diagram rates vary more sharply. Researches show that 1.5 to 2 ranges for height to width ratio is the best range hydraulically and other ranges have effect on reducing aeration and Air demand ratio β (β in this research agrees more with the relation Kalinske and Robertson presented), so the pressure in a conduit may fall considerably below atmospheric pressure which results in cavitation and vibration. To avoid these problems, suggests not to heightening the conduit more than a specific value.
Full-Text [PDF 1016 kb]   (22181 Downloads)    
Article Type: Original Manuscript | Subject: omran
Received: 2012/08/22 | Accepted: 2015/08/12 | Published: 2015/09/23

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.