Volume 18, Issue 2 (2018)                   MCEJ 2018, 18(2): 223-232 | Back to browse issues page

XML Persian Abstract Print


Abstract:   (4155 Views)
Recently, the Iranian code is established for the LRFD design of steel structures that consistent with the Iranian seismic design code (2800-4). This study is aimed to compare the performance of steel moment frames (SMF and IMF) in the Near-faults earthquakes designed with the Allowable Stress Design (ASD) and Load and Resistance Factor Design (LRFD) in a probabilistic framework. After the Static Push over (SPO), new Performance based earthquake engineering (PBEE) approach is incremental dynamic analysis (IDA) that can lead to the probabilistic judgment using fragility curves of the structure under the different types of ground motions at different levels of intensity. For the incremental dynamic analysis a large number of nonlinear time history analysis must be carried out. The evaluated steel moment frames are 4-story and 8-story frames. The nonlinear models of structures are constructed in the Perform-3D software to perform the nonlinear time history analysis. For the nonlinear modelling of beam element, the chord Rotation Model is used that proposed by FEMA and available in the Perform-3D software for the beam elements. This model predict the nonlinear behavior of element in the two end region that plastic hinge may be caused duo to the seismic load of earthquake. For the column elements, the fiber element method was employed. In this method, the cross-section of column element is subdivided into some spring elements. Each spring is subjected to axial load, given by the combination of axial force and bending moment acting on the section. This model sometimes is called multi-axial spring model (MS model). The fiber model represents a section at the structural member-end. This modelling can represent the axial-flexural interaction in the column element that their properties of nonlinear flexural bearing depends on its axial load in each time step. Near-field events due to their pulse-like effect are in the spotlight in the last decay. To evaluate their effects on the steel structures that located in the seismic areas of Iran, a number of near-field earthquakes are used in the probabilistic assessment. In the IDA curves, the roof drift is used as Damage Measure (DM) and the Spectral Pseudo-Acceleration of the first mode of the structure with 5% modal damping ( ) is used as Intensity Measure (IM). Also in the probabilistic fragility curves, the direct method is used. It means that the IM is used directly in the fragility curve. To predict the probabilistic function for the different level of performance of structures, the lognormal distribution was used. The study results show that the structures designed by the ASD method have a better seismic performance than the LRFD frames specially in the performance level of Life Safety (LS) and Collapse Prevention (CP). It can be concluded from comparison of the median of collapse functions. For example for the special moment frame (8-story structure), the use of ASD design (instead of LRFD design) leads to a 11% increase in the median of fragility function in the Life Safety (LS) level and 10% increase in the Collapse Prevention (CP) level.
Full-Text [PDF 932 kb]   (2552 Downloads)    
Article Type: Original Manuscript | Subject: Earthquake
Received: 2017/02/22 | Accepted: 2017/12/30 | Published: 2018/07/14

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.